Battery cycle up to 6 V, with which it is possible to program tests of different types of charges and discharges for different types of cells. With these tests, you can get the following information:
- Cell capacity.
- Internal resistance.
- Cell degradation in different circumstances.
It has 10 channels, being able to test 10 cells at the same time with different tests and with currents of up to 80 A in each channel.
Possibility of using up 5 channels in parallel (400A).

Specifications
| Max . curr/chan | 80 A |
| Max. P/chan | 400 W |
| Range switching | Automatic and dynamic |
| Channels | 10 |
| Voltage range | 0 – 6 V |
| Min. Disch. Volt | 1 V |
| Precision | 1mV – 10mA +0.1% up to 20A – 20mA +0.1% up to 40A – 40mA +0.1% up to 80A |
| Measurements | Voltage (4 W), current, temperature |
| Time res./rise time | 1µs / 1ms |
| Min. pulse length | 10ms |
| Current/voltage ripple | < 0.01%FS / < 0.5mV |
| Control mode | Current, voltage, power, resistance and combinations |